1. Water sample parameters -------------------------------------------------------- Number Parameter Mnemonic Mnemonic for expected error -------------------------------------------------------- 1 Salinity SALNTY 2 Oxygen OXYGEN 3 Silicate SILCAT SILUNC *1 4 Nitrate NITRAT NRAUNC *1 5 Nitrite NITRIT NRIUNC *1 6 Phosphate PHSPHT PHPUNC *1 7 Freon-11 CFC-11 8 Freon-12 CFC-12 12 14Carbon DELC14 C14ERR 13 13Carbon DELC13 C13ERR 22 137Cesium CS-137 CS137ER *2 23 Total carbon TCARBN 24 Total alkalinity ALKALI 26 pH PH 27 Freon-113 CFC113 28 Carbon tetrachloride CCL4 31 Methane CH4 33 Nitrous oxide N2O 34 Chlorophyll a CHLORA 37 Biogenic sulfur DMS compounds 40 Particulate organic PO14C carbon 42 Abundance of bacteria BACT 47 Plutonium PLUTO PLUTOER *2 64 Incubation 81 Particulate organic POM matter 82 15N-Nitrate 15NO3 83 Particulate inorganic PIM matter ---------------------------------------------------- *1 Uncertainty of the nutrients data. See nutrients data report for detail. *2 Extended table from Table 4.1 and 4.4 of WH90-1 for radionuclides measurement -------------------------------------------------------------------------- Column Headings Units Reporting Precision Parameter Parameter Mnemonic Scientific Parameter Range FORTRAN Number Mnemonic Format -------------------------------------------------------------------------- 22 CS-137 BQ/CUM Bq m-3 137Cs 0,100 F8.2 47 PLUTO MBQ/CUM mBq m-3 239,240Pu 0,100 F8.2 Error data column 22 CS137ER BQ/CUM Bq m-3 137Cs F8.2 47 PLUTOER MBQ/CUM mBq m-3 239,240Pu F8.2 -------------------------------------------------------------------------- Note: In the table 4.1 and 4.4 in WHP90-1, units of these radionuclides, TU for tritium and dpm/100kg for 137Cs, were previously used ones during GEOSECS age. It should be used Bq, SI unit, for the activities of these radionuclides. 2. CTDO parameters ------------------------------------------------------------ Parameter Mnemonic ------------------------------------------------------------ Pressure CTDPRS Temperature CTDTMP Salinity CTDSAL Oxygen *3 CTDOXY Temperature from Deep Ocean Standards Thermometer SBE35 ------------------------------------------------------------ *3 Combination of two optode data or SBE43 data. See CTDO data report for detail. 3. Quality flags ----------------------------------------------------------- Bottle quality flags ----------------------------------------------------------- 1 = Bottle information unavailable. 2 = No problems noted. 3 = Leaking. 4 = Did not trip correctly. 5 = Not reported. 7 = Unknown problem. 9 = Samples not drawn from this bottle. ----------------------------------------------------------- ----------------------------------------------------------- Quality flags for water samples ----------------------------------------------------------- 1 = Smaple for this measurement was drawn from water bottle but analysis not received. 2 = Acceptable measurement. 3 = Questionable measurement. 4 = Bad measurement. 5 = Not reported. 6 = Mean of replicate measurements. 9 = Sample not drawn for this measurement from this bottle. ------------------------------------------------------------ ------------------------------------------------------------ Quality flag definitions for CTD data ------------------------------------------------------------ 1 = Not calibrated. 2 = Acceptable measurement. 3 = Questionable measurement. 4 = Bad measurement. 5 = Not reported. 6 = Interpolated over >1 dbar interval. 7 = Despiked. 9 = Not sampled. ------------------------------------------------------------