1. Water sample parameters

--------------------------------------------------------
Number Parameter             Mnemonic   Mnemonic for
                                          expected error
--------------------------------------------------------
 1     Salinity              SALNTY
 2     Oxygen                OXYGEN
 3     Silicate              SILCAT     SILUNC *1
 4     Nitrate               NITRAT     NRAUNC *1
 5     Nitrite               NITRIT     NRIUNC *1
 6     Phosphate             PHSPHT     PHPUNC *1
 7     Freon-11              CFC-11
 8     Freon-12              CFC-12
12     14Carbon              DELC14     C14ERR
13     13Carbon              DELC13     C13ERR
22     137Cesium             CS-137     CS137ER *2
23     Total carbon          TCARBN
24     Total alkalinity      ALKALI
26     pH                    PH
27     Freon-113             CFC113
28     Carbon tetrachloride  CCL4
31     Methane               CH4
33     Nitrous oxide         N2O
34     Chlorophyll a         CHLORA
37     Biogenic sulfur       DMS
         compounds
40     Particulate organic   PO14C
         carbon
42     Abundance of bacteria BACT
47     Plutonium             PLUTO      PLUTOER *2
64     Incubation
81     Particulate organic   POM
         matter
82     15N-Nitrate           15NO3
83     Particulate inorganic PIM
         matter
----------------------------------------------------
*1 Uncertainty of the nutrients data.  
   See nutrients data report for detail.

*2 Extended table from Table 4.1 and 4.4 of WH90-1 for radionuclides measurement
--------------------------------------------------------------------------
Column Headings       Units                           Reporting Precision
Parameter  Parameter  Mnemonic  Scientific Parameter  Range   FORTRAN
Number     Mnemonic                                           Format
--------------------------------------------------------------------------
22         CS-137     BQ/CUM    Bq m-3     137Cs      0,100   F8.2
47         PLUTO      MBQ/CUM   mBq m-3    239,240Pu  0,100   F8.2
  Error data column
22         CS137ER    BQ/CUM    Bq m-3     137Cs              F8.2
47         PLUTOER    MBQ/CUM   mBq m-3    239,240Pu          F8.2
--------------------------------------------------------------------------
Note: In the table 4.1 and 4.4 in WHP90-1, units of these radionuclides, TU for
tritium and dpm/100kg for 137Cs, were previously used ones during GEOSECS age.
It should be used Bq, SI unit, for the activities of these radionuclides.


2. CTDO parameters

------------------------------------------------------------
Parameter                                          Mnemonic
------------------------------------------------------------
Pressure                                           CTDPRS
Temperature                                        CTDTMP
Salinity                                           CTDSAL
Oxygen *3                                          CTDOXY
Temperature from Deep Ocean Standards Thermometer  SBE35
------------------------------------------------------------
*3 Combination of two optode data or SBE43 data. 
   See CTDO data report for detail.


3. Quality flags

-----------------------------------------------------------
                 Bottle quality flags
-----------------------------------------------------------
1  = Bottle information unavailable.
2  = No problems noted.
3  = Leaking.
4  = Did not trip correctly.
5  = Not reported.
7  = Unknown problem.
9  = Samples not drawn from this bottle.
-----------------------------------------------------------

-----------------------------------------------------------
             Quality flags for water samples
-----------------------------------------------------------
1  = Smaple for this measurement was drawn from water bottle
     but analysis not received.
2  = Acceptable measurement.
3  = Questionable measurement.
4  = Bad measurement.
5  = Not reported.
6  = Mean of replicate measurements.
9  = Sample not drawn for this measurement from this bottle.
------------------------------------------------------------

------------------------------------------------------------
          Quality flag definitions for CTD data
------------------------------------------------------------
1  = Not calibrated.
2  = Acceptable measurement.
3  = Questionable measurement.
4  = Bad measurement.
5  = Not reported.
6  = Interpolated over >1 dbar interval.
7  = Despiked.
9  = Not sampled.
------------------------------------------------------------